Electrical system – 5000 Diagnostic and troubleshooting Order number 235568-040
*
Date 2006-04-10
ALARM INCORRECT START
*
Valid from serial number 904526-
T-code 795
If an error condition is present on the truck it will be immediately displayed. • Refer to Table 15, “List of error codes,” on page 28.
Fig. 16 Typical error display
NOTE! The status LED is continuously on while the hand terminal is connected.
Error code history To check the error code history log carry out the following: With the hand terminal connected as described in previous section... Navigate to the ALARM menu. SEM-X 24v
75A
V.. 00000
ENTER *
MAIN MENU * PARAMETER CHANGE MAIN MENU * STEER TABLE MAIN MENU * PROGRAM VACC MAIN MENU * ALARMS
*
ROLL * *
CODE ROLL
CODE
OUT
CODE ENTER
CODE 00001
#01
20 C
OUT ENTER
OUT
ENTER OUT
G
LOG BOOK CLEARED (PRESS OUT)
Fig. 17 Menu tree for error code history display
A *
00015h
VFIELD NOT OK * #01 27°C
B
C
D
The log will display up to 5 most recent error types with the following information for each error. A - Error code description. B - Hour meter value when fault occurred. C - Number of occurrences of specific error. D - Transistor regulator temperature when fault occurred. The error code history log can be optionally cleared when exiting the ALARM menu.
© TIEE SARL
Service Manual
SP10, SP10S
10- 27