Electrical systems – 5000 Parameters T-code 497
Valid from serial number 723984-
Date 2005-11-04
Order number 222996-040
13.6.2 Parameter description Parameter 1 Possibility to adjust the speed in the low speed range (when the safety gates are not used).
Parameter 2 Possibility to adjust the speed in the high speed range (when the safety gates are used).
Parameter 3 The lower value of the parameter the longer time it takes to accelerate the truck to top speed.
Parameter 4 Defines motor brake force when lever (L1) goes to neutral position.The lower value of parameter the longer time to reduce speed.
Parameter 5 The time until the truck will be switched off when a key pad is used. Time is counted from when the latest power consumer is used. Value = 0 gives 4 hours.
13- 26
Service Manual
7PLL24
© TIEE SARL