Electrical systems – 5000 Parameters

13.6 Parameters

•Press S18 and turn S17 to on at the same time.

•Press S18 until you read P= parameters.

•You have now choosen P=parameters the symbol “C” on display will be highlighted to indicate what’s currently shown on display.

•Scroll to the parameter you want to change or look at by pressing the L1 up or down.

•Press S18 ones to get access to the parameter.

•Set parameter value by pressing L1 up or down.

•Press S18 ones to confirm change.

•Turn S17 to off.

You have now completed a parameter change and the next time you start the truck the new parameter setting will be valid.

NOTE !

Truck handling.

Modifying specific truck parameters will change the driving characteristics of the truck. Do not change any parameters without the necesarry know-how.

13.6.1 Driver parameters

time it takes for the truck to switch off when the keypad is used. The time counts down from the moment the last power-consuming unit is used. Value = 0 gives 4 hours