1 minute read

Electrical systems – 5000 Parameters

Order numberDateValid from serial numberT-code 222996-0402005-11-04723984-497

The parameter symbol is lit (i.e. stops flashing).

•Select independent variable #1 by activating the speed control L1. Independent variable value #1 is displayed after 1 second.

•Press the horn button S18.

The parameter symbol flashes.

•Enter the independent variable value #1 by repeatedly operating the speed control L1 in either direction. See the list of optional functions in Table 2:

•Press the S18 horn button once to confirm the new setting.

The parameter symbol is lit (i.e. stops flashing). Adjust independent variables #2, #3 and #4 in the same way as above.

•Switch off the truck by pressing on the keypad. The optional function is now activated.

•Check that the optional function works correctly before the truck is put back in operation.

Table 2: List of configurable optional functions

Independent variable #1 variable #2 variable #3

Independent variable #0 = 1: The option button controls the spider output

Independent variable #0 = 2:Reduced running speed controlled by the spider’s digital input

Independent variable #0 = 3:Activate the spider output for specific movements output 1 output 2

This article is from: