1 minute read

Electrical systems – 5000

authorization the driver has for the parameters.

Odd values specify open driver parameters, even values specify that driver parameters must be opened using the CAN key

13.6.4 Parameter description

Parameter 10 NOTE!

The functionality of parameter #10 is set aside if the value of parameter #39 is set to 5,6,7 or 8. The PIN codes are managed using the socalled expanded keypad. See section “Expanded keypad - General” on page 41 for more detailed information.

Ten drivers can have their own PIN code to gain access to the truck. Each driver can set all driver parameters individually.

On delivery the PIN code is set to 1 and this only applies for driver no. 1. Code 0 is not accepted as a solitary code.

When you wish to start the truck enter your code and press the green button numbered 1.

When you want to switch off the truck, press the red button numbered 0.

When the CAN key is connected, you can start the truck by simply pressing the green button numbered 1. Switch off by pressing the red button numbered 0.

Parameter 14

Specifies the speed you will have when you reach the first speed sensor.

Parameter

15

- Non-configurable option

See “Option parameters” on page 29