Monitoring grapple: Activate camera C. Adjust the monitor image so that you can see the working tool. Adjusting camera:

Fig. 3-52 1

Camera (shown without protective cover)

Camera

2

Screw

The cameras for the machine can be accessed from the platform. To access the camera at the stick, you might need some auxiliary equipment. Use only suitable devices (e.g. lifting platform). The camera is encased in a protective cover. The screws are accessible through openings in the protective cover. Lower the working attachment and thus the camera attached to the stick to the lowest possible position. Switch off the diesel engine and push the safety lever upwards. Loosen the screws. Turn the camera to the desired angle. Tighten the screws. Switch on the monitor and check the image. If necessary, readjust the camera position. Note! Depending on the equipment, the stick might feature several mounting points for the camera. The mounting point for the camera must suit the working tool you wish to use. If the camera needs to be attached to another position on the stick, contact the LIEBHERR customer service centre. For detailed information, refer to the operating manual of the camera manufacturer.