1 minute read

Control, operation

Operating and control elements

Fig. 3-8 Operator's menu

Scrolling through the operator's menu: Press the arrow buttons UP and/or DOWN.

The previous or next menu is displayed on a black background. Depending on the equipment of the machine, there might be more menus in addition to the above listed. These can be accessed by scrolling to the bottom of the screen.

Select a menu:

The menu showing a black background is selected. Press the Menu button. The submenu of the selected function is displayed. Press the BACK button. The submenu is closed.

SymbolDescription

Reset daily operating hours counter

Confirmation of service interval ings for working tool (optional equipment)

Operating hours, machine data

Status of hydraulic pumps and electrical inputs/outputs

Detected and saved errors

Time copyright by

Reset menu for daily operating hours counter

Fig.

3-9 Resetting the daily operating hours counter

Use this menu to reset the daily operating hours counter. Press the UP button.

Option OK is not stricken through and is highlighted in black. Press the Menu button.

The operating hours counter is reset.

The UP and DOWN buttons and the Menu symbol are no longer visible. Press the BACK button. The submenu is closed.

Menu: Service interval confirmation

This menu provides information concerning scheduled service checks. It also allows for the confirmation of completed serv ices. The current operating hours (e.g. "478Hrs") are displayed together with the scheduled service interval (e.g. "500Hrs").

The service can be completed earliest 50operating hours before it is due. As soon as the pre-set operating hours are reached, the operator is requested to indicate whether the service tasks have been completed.

Service has been carried out: Press the UP button.

The OK symbol is not stricken through and is highlighted in black. Press the Menu button.

The service is confirmed to have been completed at the current operating hours.