Table 1: 14-Pin Switch and Pin Assignments Switch Switch Position 1 2 3 4 5 6
Switch Type
Wire Color
Forward Gray Momentary Reverse Orange Forward White Momentary Reverse Purple Forward Blue Momentary Reverse Tan On Latching On/Off Pink N/A Momentary N/A N/A Momentary N/A
Pin Description Ground Not Used 12V Power Not Used Not Used Not Used Not Used
Connector Max. Current Pin (Amps) D C F E H G A N/A N/A
Connector Pin B J K L M N P
Notes
15
Open
15
Open
15
Open
10 N/A N/A
Open Vehicle Horn Vehicle 2‐Spd On/Off (Option)
Max. Current (Amps) 20 N/A 15 N/A N/A N/A N/A
Switches 1, 2, and 3 have a combined total capacity of 15A. Switches 1, 2, 3 and 4 have a combined total capacity of 20A. Note: Depending upon the attachment, an adapter harness may be necessary. Refer to the documentation supplied with the attachment, or contact your dealer.
Fan Reverse To reverse the direction of the engine’s hydraulically driven engine fan, press the lights/beacon button and the self-leveling button (Fig. 14) together for 10 seconds. An icon will appear on the multi-function display to indicate reverse mode. The fan will slow and enter the reverse direction for 30 seconds. It will then slow and return to normal operation. Engine speed should be at 1800 rpm or higher. Fan speed is limited to 1500 rpm Fig. 14 Press these two buttons to in its reverse mode. begin the fan reverse function. 50950233/G0221