Engine Diagnostic Chart (end) DTC SPN
FMI
Trouble Code Type
Error Description
524081
9
Plausibility Error
NOx sensor upstream SCR-CAT, lambda value below lower physical threshold
524108
9
Timeout Error
Missing CAN message of EGR throttle valve; Timeout Error of CAN-Transmit-Frame ComEGRTVActr, Missing CAN Bus message
524109
9
Timeout Error
Missing message of EGR throttle valve; Timeout error of CAN-Receive-Frame ComRxEGRTVActr, Missing CAN Bus message
524133
2
Electrial Error
State of digital input standstill release switch
524134
0
Threshold Error
DPF ash load exceeds the shutoff threshold
524135
0
Threshold Error
DPF ash load exceeds the warning threshold; DPF soot load exceeds the shutoff threshold
524135
14
Threshold Error
DPF soot load exceeds the service request threshold
524147
7
SCR System Error
SCR system reverting valve blocked SCR system pressure build-up not possible Set together with DFC_SCRCoBldUpLoPres. DFC_SCRCoBldUpLoPresRst is only used for inducement purposes. It ensures that legal inducement is working correctly
524147
13
Plausibility Error
524152
2
Timeout Error (CAN)
Urea quality sensor; Timeout CAN message
524153
2
Timeout Error (CAN)
Urea tank level and urea tank temperature via CAN bus, timeout of CAN message
524175
0
Threshold Error
SCR-CAT Nox emissions above maximum threshold
524178
7
Out-of-Range Error (CAN)
SCR system DEF pressure out-of-range
524190
14
DEF Error
Inducement level 1 active; Not enough urea in tank, low urea quality, hardware tampering failure is detected, or hardware failure is detected
524191
14
DEF Error
Inducement level 2 active; Low DEF tank level, a low DEF quality is detected, hardware tampering(system components are pinched off) or hardware failures as shortcut to battery, shortcut to ground etc. are detected
524193
8
Timeout Error
Standstill regeneration mode time exceeds longlimit threshold; machine too long or too often in standstill mode
524194
8
Timeout Error
Standstill regeneration mode time exceeds short-limit; Machine too long or too often within a short time in standstill mode
524195
14
Timeout Error
Standstill request due to crystalisation ignored too long
DTC SPN
FMI
Trouble Code Type
Error Description
524267
14
2nd Level Inducement Error
General inducement error. Refer to official Deutz engine error code documentation for more information
102
50950233/G0221