Engine Diagnostic Chart (cont.) DTC SPN
FMI
Trouble Code Type
Error Description Error at static plausibility check: absolute temperature difference of sensed temperature upstream SCR catalyst and ambient temperature > as static plausibility limit at engine cold start (engine was off for at least 8 h), temperature upstream of SCR catalyst is expected to be identical to ambient temperature =>
4360
2
SCR-Cat Temperature Plausibility Error
Error at dynamic plausibility check: temperature difference of sensed temperature upstream SCR catalyst and ambient temperature < as dynamic plausibility limit dynamic check is blocked if static plausibility check is already faulty => Temperature upstream SCR catalyst must be by 40°C higher than ambient temperature if engine runs and a certain delay time has expired
4361
3
DEF Error
DEF catalyst upstream temperature sensor: the voltage of sensor measured by ECU is out of the target range
4361
4
DEF Error
DEF catalyst upstream temperature sensor: the voltage of sensor measured by ECU is out of the target range
4365
3
Urea Tank/DEF Error
Urea tank temperature sensor: the current drain measured by ECU is above the target range; DEF qualitysensor, tank temperatur; short circuit to battery or open load
4365
4
Urea Tank/DEF Error
Sensor error urea tank temperature; short circuit to ground; DEF qualitysensor, tank temperature; short circuit to ground
4365
12
Urea Tank Error
Urea tank temperature above the warning threshold
4365
13
Urea Tank/DEF Error
DEF qualitysensor, tank temperature; temperature out of physial range SCR Tank heating valve; short circuit to ground
4366
4
Short-Circuit Error (SCR)
4366
5
SCR Error
SCR tank heating valve primary side; open load
4375
3
Short-Circuit Error (SCR)
Urea pump motor; short circuit to battery
4375
4
Short-Circuit Error (SCR)
Urea pump motor; short circuit to ground
4375
5
SCR Error
Urea pump motor; open load
4376
3
Short-Circuit Error (SCR)
SCR reversal valve; short circuit to battery
4376
4
Short-Circuit Error (SCR)
SCR reversing valve; short circuit to ground
4376
5
SCR Error
SCR reversal valve; open load
50950233/G0221
95