OPERATING INSTRUCTIONS 6015 / RH40E Inspection and servicing Refuelling station (optional) Drive the machine until the fuel tank is almost empty. Check how much fuel is left in the tank and place a recipient of sufficient capacity under the drain plugs of the tank. Turn out the drain plug (5, Fig. 3-37:) of the fuel tank and drain off the fuel. Flush the tank with diesel fuel. Screw the drain plug (5) back into the tank.
Sparking caused by static or electric charges may set fuel on fire.
Check earthing strap (equipotential bonding) (4, Fig. 3-38:) regularly for tightness. Only a perfectly connected earthing strap can remove static or electric charges and thus avoid the risk of fire during refuelling.
Fill in fuel through the strainer in the filling nozzle (2).
Fig. 3-38:
BA RH40E(3 725 069.00)-EN