OPERATING INSTRUCTIONS 6015 / RH40E Inspection and servicing

Main filter elements

An insufficient air-intake performance, caused by a contaminated main filter element, is indicated by the vacuum-meters (8, Fig. 3-26:).

Clean or replace main filter element only if the vacuum-meter (8, Fig. 3-26:) indication changes to "RED" w ith the engine running at high speed.

New or cleaned main filter elements should always be at hand to shorten excavator downtimes.

Removal and installation

 Loosen clamps (1, Fig. 3-27:) at the air filter housing and remove cover (2).

 Withdraw main filter element (3). Do not remove safety filter element (4).

 Replace or clean main filter element.

 Before installing the filter element, clean contact faces at cover (2) and at filter housing.

 Put on cover (2) using clamps (1).