1 minute read
OPERATING INSTRUCTIONS 6015 / RH40E Inspection and servicing
Main filter elements
An insufficient air-intake performance, caused by a contaminated main filter element, is indicated by the vacuum-meters (8, Fig. 3-26:).
Clean or replace main filter element only if the vacuum-meter (8, Fig. 3-26:) indication changes to "RED" w ith the engine running at high speed.
New or cleaned main filter elements should always be at hand to shorten excavator downtimes.
Removal and installation
Loosen clamps (1, Fig. 3-27:) at the air filter housing and remove cover (2).
Withdraw main filter element (3). Do not remove safety filter element (4).
Replace or clean main filter element.
Before installing the filter element, clean contact faces at cover (2) and at filter housing.
Put on cover (2) using clamps (1).