OPERATING INSTRUCTIONS 6015 / RH40E Inspection and servicing

Filling in new oil / Topping up

 Unscrew plug (4, Fig. 3-82:) and fill in new oil.

 Check oil level with dipstick (1, Fig. 3-82:).

 Screw in plug (4) again.

Gearbox venting

The gearbox is vented through breather filter (2, Fig. 3-82:).

Clean breather filter in accordance with the servicing plan.

 Unscrew breather filter (2), clean in white spirit or paraffin oil and blow dry with compressed air.

 Screw breather filter (2) back in place.

Output pinion

Grease bearing regulary.

 Fill in approximate 50 cm3 / 1,7 oz grease through grease nipple (5, Fig. 3-83:) by means of a hand grease pump.