STARTING PROCEDURE To start the engine of the Loader, place all the controls in neutral. Depress the accelerator pedal half way and push the fuel stop lever all the way in. Pull out the choke control (gasoline only). Turn the key switch fully clockwise until the engine starts. Release the key. '

1. Immediately check the oil pressure gauge for low or no oil pressure and the ammeter for no charging rate. If .either of these conditions are present stop the engine and investigate. 2. If the engine fires and stops, wait for the starting motor to stop spinning before again turning the key switch to start. 3. Do not use the starting motor longer than 30 seconds without interruption. Wait at least 3 minutes so batteries can recuperate and the starting motor can cool.

110 TE While the Diesel engine is being turned over with the key switch, white or black exhaust smoke should be observed. If none is observed and and the engine will not start, it is an indication that no fuel is being delivered to the cylinders. STOPPING PROCEDURE DIESEL ENGINE

Release accelerator pedal for engine to reach idle and pull the Shutoff lever all the way out. The shutoff lever must be all the way in to restart the engine. SPARK IGNITION ENGINE

Depress the accelerator pedal to accelerate the engine to approximately 1200 RPM to bleed dry the carburetor idle system, then turn the key switch to the off position to actuate the solenoid shutoff on the carburetor to cut off the fuel supply. This will stop ~the engine and prevent an after run.

COLD WEATHER OPERATION To start and operate your Case Loader during cold weather, the following precautions must be observed: