DRY AIR CLEANER MAINTENANCE INSTRUCTIONS Perform maintenance of the air cleaner in the following way: 1. Remove the right side plate of the hood 2. Release the clamps of the air cleaner lid (marked with arrows) 3. Remove the air cleaner lid (1)
RECOVERY OF THE MAIN AIR CLEANER ELEMENT −Remove the main element of the dry cleaner (2) by pulling If the main element is not damaged (there must not be any dust on the inner side of the element), recover it by blowing pressurized air from the inner side of the element. This way you can recover the main element 3 times at the most. The element must be replaced once a year.
REPLACING THE SAFETY ELEMENT OF THE AIR CLEANER −Remove the safety element of the dry cleaner (3) by pulling. The safety element cannot be recovered. It must always be replaced in these cases. -If the main element is damaged. -After covering 2000 hours of work -At least once every two years.