Input/Output Signals of the AML System (TR-150-4/GR-150-1) CN 2 connector Pin No.

5

7

8

9

11

name

Signal names and functions

RLY 5

Signal name: Telescoping control relay output <4th/top boom sections telescope> The relay turns ON (DC24V) under either of following condition and 4th/top boom sections telescope. 1. The boom length is 12.9m or more. 2. The boom length is 12.5 -- 12.9m and 4th/top boom extension switch is "ON" (Di28 / 0V). 3. The boom length is 12.5 -- 12.9m and 4th/top boom full retraction detection switch is "OFF" (Di3 / 24V). <2nd•3rd boom section telescope> The relay turns OFF (DC0V) (under either of following condition) and 2nd•3rd boom section telescope. 1. The boom length is 12.5m or less. 2. The boom length is 12.5 -- 12.9m and 4th/top boom full retraction detector switch is "ON" (Di3 / DC0V). Relay ON (DC24V): 4th/top boom sections telescope. Relay OFF (DC0V): 2nd•3rd boom section telescope.

RLY 7

Signal name: Two-blocking alarm relay output This relay contact turns ON and the alarm buzzer is output when the hook block is two-blocking. Relay ON (DC24V): Alarm buzzer is output. Relay OFF (DC0V): Alarm buzzer is not output.

RLY 8

Signal name: HOOK-IN control relay output When the HOOK-IN operation is performed, this relay contact turns ON, automatic stop (AML vent) relay output RLY1 turns OFF, and the pressure in the winch hydraulic circuit drops. Relay ON (DC24V): The pressure in the winch hydraulic circuit drops. Relay OFF (DC0V): The pressure in the winch hydraulic circuit is normal. When all the following conditions are satisfied, the AML assumes that the HOOK-IN operation is performed. (1) PTO switch is ON. (2) Boom lift or single top lift status is registered in the AML. (3) Boom is fully retracted. (*1) (4) Boom angle is 2° or less. (*1): When the 2nd/3rd boom section full retraction detection switch contact is closed, the AML assumes that the boom is fully retracted.

Di11

Signal name: Main winch hoist-up operation detection switch input Input from the switch detecting hoist-up operation of the main winch. Switch ON (DC0V): No hoist-up operation of the main winch is detected. Switch OFF (DC5V): Hoist-up operation of the main winch is detected.

Di13

Signal name: Aux. winch hoist-up operation detection switch input Input from the switch detecting hoist-up operation of the auxiliary winch. Switch ON (DC0V): No hoist-up operation of the auxiliary winch is detected. Switch OFF (DC5V): Hoist-up operation of the auxiliary winch is detected.

13

CNTL 1P

Signal name: Right swing proportional control valve output Current controlled by the AML is output from the AML to the right swing proportional control valve when the right swing is stopped by automatic swing stop. Output voltage: Square wave 0 to 24V

14

CNTL 1N

Signal name: Ground terminal for right swing proportional control valve Input voltage: DC0V

27

W301-0139E