1 minute read

Adjustment Value Table

Specification No. : GR-600-1-00213 (2M2D-specification)

AML model : AML-L C

AML code No. : 361-933-90000

1. Setting before adjustment Capacity setting Head-off

2. Adjustment the detector

Precautions for adjustment

(*1) Adjust the center of dispersion to coincide to the adjusting value.

(*2) Adjust the boom angle and the moment in the elevating lowering operation.

(*3) Adjust the swing angle in the clockwise swing operation.

(*4) When adjusting the moment, make the number of parts of line to the standard number (four parts of line) that is when boom fully extended, and set the AML as Boom status: Boom and Number of parts of line:4. The adjusting value is for 0.40 ton hook installed, and the value in the { } is for 0.47 ton hook installed.

Adjustment Value Table

Boom length: Fully retracted adjustment Boom angle: 80.0±0.1° value)

Lifting capacity : Without load (0.40t {0.47t} hook only) Hook : Two-blocking status

Boom length: Fully retracted angle: 10.0±0.1°

Lifting capacity : Without load (0.40t {0.47t} hook only)

: Hoisting-down until immediately before the ground

Boom length: Fully extended radius: 29.99ft (9.14m)

17.60klbf

Boom length: Fully extended angle: 30.0±0.1° value) Lifting capacity : Without load (0.40t {0.47t} hook only) Hook : Hoisting-down until immediately before the ground

Refer to “terminal No.5 (RLY5) of CN2 connector (page 35)” for the telescoping control relay output of the AML.

Adjustment Value Table

Specification No. : GR-800-1-00211 (2M2D-specification)

AML model : AML-L C

AML code No. : 361-932-20000

1. Setting before adjustment Capacity setting

2. Adjustment the detector

Precautions for adjustment

(*1) Adjust the center of dispersion to coincide to the adjusting value.

(*2) Adjust the boom angle and the moment in the elevating lowering operation.

(*3) Adjust the swing angle in the clockwise swing operation.

(*4) When adjusting the moment, make the number of parts of line to the standard number (four parts of line) that is when boom fully extended, and set the AML as Boom status: Boom and Number of parts of line:4. The adjusting value is for 0.40 ton hook installed, and the value in the { } is for 0.47 ton hook installed.

Adjustment Value Table

Boom length: Fully retracted adjustment Boom angle: 80.0±0.1° value)

Lifting capacity : Without load (0.40t {0.47t} hook only) Hook : Two-blocking status

Boom length: Fully retracted angle: 10.0±0.1°

Lifting capacity : Without load (0.40t {0.47t} hook only)

: Hoisting-down until immediately before the ground

Boom length: Fully extended radius: 45.01ft (13.72m)

Boom length: Fully extended angle: 40.0±0.1° value) Lifting capacity : Without load (0.40t {0.47t} hook only) Hook : Hoisting-down until immediately before the ground plane

Refer to “terminal No.5 (RLY5) of CN2 connector (page 35)” for the telescoping control relay output of the AML.