OPERATION
EXPLANATION OF COMPONENTS
CGC MONITOR CGC MONITOR
●
The CGC monitor displays the condition of the machine, the maintenance situation, and messages for the operator and service man, and is also used to input the necessary data.
●
The surface of screen (1) is equipped with touch buttons to input the data and change the screen.
●
When the starting switch is turned ON, the opening screen is displayed for approx. 10 – 20 seconds. The condition of the machine is not displayed.
●
If the ambient temperature of the monitor goes below –30°C or above 55°C, the back lighting is turned off to protect the screen. The display cannot be seen, but this is not an abnormality. When the temperature returns to within the range of –30°C to 50°C, the display will appear again, so carry out operations according to the CGC monitor.
3-19