1 minute read
CONTROL DEVICES
In the room under the cab
AUTO-GREASING SWITCH
This switch (1) is inside the base under the cab and is used to switch between automatic and manual greasing. Normally, keep this switch at the AUTO position. When using a grease gun, set the switch to MANUAL.
AUTO GREASE/GREASE GUN SELECTOR LEVER
This lever (2) is used to select automatic or manual greasing in the same way as the auto-greasing switch. Normally, keep this lever at the AUTO GREASE position. When using a grease gun, check first that the grease pump is not carrying out auto-greasing [if it is carrying out auto-greasing, wait until the grease pump stops (within approx. 1 minute)], then set the lever to the GREASE GUN position.
Auto Greasing Selector Lamp
This lamp (3) informs the operator if the auto-greasing system is in auto-greasing status or in manual greasing status. When it is in auto-greasing status, the green AUTO lamp lights up.
When it is in manual greasing status, the green MANU lamp lights up.
AUTO-GREASING CAUTION LAMP
This lamp (4) lights up if an abnormality occurs in the autogreasing system. Check the engine from the content of the display on the auto-greasing controller inside the cab base, then carry out repair work.
Set the auto-greasing controller to the OFF position when carrying out repair work. If the starting switch is turned OFF, the controller is also turned OFF.
Remark
● To turn the auto-greasing controller OFF/ON, press power switch (1). Each time the power switch is pressed, it switches OFF → ON → OFF.
● If the engine has not been studied, and the standing switches left at the ON position, CONTROLLER REST FAILURE is displayed on the auto-greasing controller display and the auto-greasing caution lamp lights up, but this does not indicate any abnormality. When the starting switch is turned OFF, the condition returns to normal.
LampController displayNature of abnormalityCause
Controller rest failurePressure inside grease piping does not rise when pump is working
Lights up
Vent pressure SW alarmVent valve does not return, injector cannot be recharged
● Failure of pump
● Pump running empty
● Cracked grease piping, leakage
● Failure of vent valve
● Crushed, clogged grease piping upstream from injector
Operation
Use the table below to select auto-greasing or manual greasing, and operate the switch lever securely. Normally, said the switch to the auto-greasing position.
No Control devices
Selection of greasing method
Auto-greasing Manual greasing (using grease gun)
1Auto-greasing selector switchSet to AUTO positionSet to MANUAL position
2Grease circuit selector leverSet to AUTO GREASE positionSet to GREASE GUN position
3Auto-greasing selector lever Check that green AUTO lamp lights up Check that green MANUAL lamp lights up
4Auto-greasing caution lampRed lamp lights up when abnormal