GROVE Crane Manitowoc RT800E Operator Manual - PDF DOWNLOAD

Page 184

RT800E OPERATOR MANUAL

Lubrication

Item

Lube Point Description

Figure No.

Approved Lubricant

Figure 5-11

AGMA Extreme Pressure Gear Lubricant 6829100213

Figure 5-11

AGMA Extreme Pressure Gear Lubricant 6829100213

Lube Capacity

Lube Interval

Application

Hoist

90

91

NOTE:

92

NOTE:

5-28

Main Hoist

Auxiliary Hoist

15.5 qt 14.7 l

15.5 qt 14.7 l

• Check and fill every 50 hours or weekly • Drain and fill every 1000 hours or 12 months • Check and fill every 50 hours or weekly • Drain and fill every 1000 hours or 12 months

Oil level must be visible in the sight glass (see note)

Oil level must be visible in the sight glass (see note)

Line up the Fill/Drain Plug with the upper cutout hole (A). Let hoist sit idle for 20 minutes for an accurate reading. Ensure hoist is level and oil is within 21°C ±11°C (70°F ±20°F). If oil level is not visible in sight glass, the hoist may be underfilled. Oil escaping from vent plug is an indication the hoist may be overfilled. If hoist is over filled move the Fill/Drain Plug to the lower cutout hole (B) and drain until oil level falls within the sight glass.

Cable Follower (Arms)

Figure 5-11

EP-MPG Extreme Pressure Multipurpose Grease 6829003477

Thoroughly coat

250 hours or 3 months

Spray on

Lubricate more frequently than interval indicated in table if environmental conditions and/or operating conditions necessitate.

Published 04-05-2017 Control # 307-08