BI619026

_________________________________________________ Installation This process applies to the CLA Gear case and Pot Lube Check. Presently, the lube checks require the removal of the check plugs, which are beside the fill port, and observation of the gear’s lube flow from the check port. It has been found that this does not insure the true gear lube level. To assure the proper gear lube level apply the following procedure. 1. Remove all plugs. 2. Using a rose gun or lube bucket force gear lube in the fill port until lube flows from the check port.

The diagram below gives a description of the location of the ports for both the upper and lower ports.

© DBT AMERICA 2005

Inspect CLA’s for excessive wear and damage, and replace as necessary.

¢ Cutter gear case mounting is secure, and tighten as necessary ¢ CLAs for looseness, and tighten as necessary Lubricate scrubber fan motor.

_____________________________________________________________ DBT – 25M SERIES CONTINUOUS MINER © VUVR / 03 4.9