Initial 500 Hours Service Maintenance to be performed after the first 500 hours only.

1. Engine 1.1. Check/adjust PDE injector rocker arms • Checking/adjusting PDE injector rocker arms shall also be carried out after the first 500 hours of operation. • Contact Moxy Dealer for checking/adjusting of the PDE injector rocker arms • The checking/adjusting of the PDE injector rocker arms

2. Transmission 2.1. Run the AEB-Tester AEB = Automatic Filling Parameter Adjustment

To optimise the transmission, run the AEB-Tester. 1. Remove the cover on the backwall (remove the instructor's seat back rest, if that is fitted). 2. Follow the procedure described in the table on next page. The gear display will show the AEB's actions. ("Display message" in the table on the next page).

TCU = Transmission Control Unit

* Numbers refer to positions on the lubrication schedule, chapter 6 146