The Bank Waterspray feature can be used by the operator in two different ways. The operator can manually enter the start and end points (this allows a spray area to be at any location on the face) or the operator can use the Group Select keys and select a group of 10 or 20 adjacent shields. Shields that are part of a Bank Waterspray post the Last Auto Fct as "Bank Spray".
Operator Display & Keystrokes Scroll to the Bank Waterspray display using the Menu Navigation keys:
: Bank Waterspray : xxx d yyy typestring From this display, the following actions can be taken: Press
Results
+
Selects a group of 10 shields to the left and triggers a waterspray function on each.
+
Selects a group of 10 shields to the right and triggers a waterspray function on each.
+
+
Selects a group of 20 shields to the left and triggers a waterspray function on each.
+
+
Selects a group of 20 shields to the right and triggers a waterspray function on each. Triggers a waterspray function based on existing parameter values shown in the display. Often the values are entered by the operator just prior to using this key; this is done by scrolling right from the Bank Waterspray display and manually changing the values.
Keystroke Details From the default display, the operator scrolls right twice to reach the Bank Waterspray display.
57
+