1 minute read
Maintenance Lock
These display lines are shown as the default display; line2 of the display will continue to show the normal sensor and shearer position information.
Display Help Text
#129 ULOCK !!! Umbrella Lock is active; this is the center shield.
#129 ULOCK >X more
#129 ULOCK Overlap Umbrella Lock is active here and X shields to the right.
This shield is in two umbrella lock zones; zones cannot be cleared or moved from this shield.
Umbrella Lock Messages
These displays are shown when the Umbrella Lock zone is initiated or moved. They only display for Key-time and then they go away.
Display Help Text
Umbrella activated. Not for maintenance!! Umbrella Lock is not intended for maintenance; use the black Local Lockout or Maintenance Lock..
Umbrella activated. For travel only!! Umbrella is intended only for traveling across face; not for maintenance.
When shields are first included in the Umbrella Lock zone, a short audible warning will sound. When moving the Umbrella Lock zone causes some shields to be released (i.e., no longer within the zone), those shields will provide an audible warning that the Umbrella Lock no longer covers those shields. This warning is longer than the new-Umbrella Lock warning and the Umbrella Lock restrictions are not actually released until the warning sound is completed.
M a i n t e n a n c e L o c k