
1 minute read
In-Shield Automatic Keys
When in Master Mode (i.e., after pressing a Neighbor Select key) the man-in-place keys are used to manually operate the selected shield. When the key is pressed, the function is activated. When the key is released, the function is released.
A-key Shield Lower
B-key Shield Advance. If the “Baselift with B/D key” is turned on the base lift will turn on while advancing.
C-key Shield Set
D-key Lower to parameter “Advancing Pressure”, then advance while continuing to lower. If the “Baselift with B/D key” is turned on the base lift will turn on while lowering and advancing.
E-key Tip Up
#-key Tip Down
+/- key Baselift
1-key Conveyor Push
These keys control automatic functions in-shield when no other shield is selected (i.e., when in Idle Mode, not in Master Mode).
2-key Positive Set Automatic key (PSA) Pressing this key toggles the PSA function On or Off on this shield. When PSA is toggled On, the shield may begin to set, depending on the leg pressure at the moment.
3-key Locking Push key Pressing this key activates the Locking-Push feature on this shield. Last Auto is posted as “Manual Push”. If the key is pressed again, the Locking Push feature will be stopped.