BI632977
____________________________________________________ Maintenance Every 6 months hydraulic oil tank
Change the hydraulic fluid in the feeder breaker oil tank (Fig. 43). Clean all dirt and debris from and around the fill cap and drain plug. Remove the drain plug and allow the oil tank to completely drain. Clean and reinstall drain plug. Add oil as required via the power fill system until fluid is visible in sight glass. Install fill cap. Start the machine and allow the hydraulic pump to run in order to purge air from the system. Shut down the machine and recheck the oil level. Add oil if necessary. Fig. 43: Hydraulic tank oil level
Oil level sight glass
Drain plug
______________________________________________________________ REV 2 5.61