Case 9007 Crawler Excavator Operator's Manual 6-6361 - PDF DOWNLOAD

Page 178

MAINTENANCE/ADJUSTMENTS

1.

Wipe clean the rod and bearing on the cylinder to be cleaned.

2.

Operate normally for five or ten minutes.

3.

Extend the cylinder rod.

4.

Carry out the leak test. ROD APPEARANCE

TEST

CONCLUSION

Dry

Slight traces of oil when a piece of paper is wiped over 20 cm of the rod.

Normal

Slightly oily

Paper remains stuck to rod when run over rod.

Normal

Oily

Paper remains stuck when placed on rod.

Normal

Very oily or weeping

Each time cylinder rod is extended, a ring of oil can be seen on the rod.

Leakage

Each time the rod retracts, the excess oil drips from the gland.

Consult your CASE Dealer

PLASTIC AND RESIN PARTS

TRIM THIS EDGE

A cylinder rod should be slightly oily. Check that there are no leaks after a period of work, when the whole hydraulic system is at normal operating temperature.

Alt= to hide template information Alt+ to display template information

CHECKING FOR CYLINDER LEAKAGE

The use of gasoline, paraffin, paint solvents, etc. will cause discoloration, cracks or deformation of these parts.

175

TRIM THIS EDGE RIGHT PAGE

Template Name: OM_1_col Template Date: 1994_04_29

When cleaning plastic screens, for example on the instrument console or the control arms, do not use gasoline, kerosene, paint solvents, etc... Use soap and water and a clean cloth only.