AIR FILTER SYSTEM Service Specifications As required ...................................................................... Clean air filter intake cap Every 10 hours of operation or daily ...................... Check dust valve and dust cup Every 1000 hours ........................................................Replace air cleaner element 2. Remove the rubber baffle from the dust cup and clean both the baffle and dust cup with a cloth.

1. The shelf life of a new air filter element is five years. Do not install a new element that is more than five years old. The date of manufacture is on the end of the cap of the filter element.

3. Do not remove the filter elements fro m the ma ch in e to c he ck fo r r e s t r i c t io n . A lw a y s f o ll o w t h e recommended service instructions in this section.

BP96C029

3. Install the rubber baffle in the dust cup and install the dust cup as shown. Make sure the arrows point up.

4. Each time you service the air filter system, make sure all hose connections are tight. Replace all damaged parts.

Dust Cup Check the dust cup and make sure there are no obstructions inside. 1. Loosen the clamp and remove the dust cup.

B876458W

BP96C028

81

TRIM THIS EDGE RIGHT PAGE Bur 9-25773

TRIM THIS EDGE

2. Replace both filter elements after one year in the machine.