1 minute read
Toyota Model 7HBW23 Service ManualSection 5. Troubleshooting
from Toyota Forklift 7HBW23 4,500 lb. Powered Pallet Walkie Service Manual SN 24501 and up - PD DOWNLOAD
Control Handle Display and Programming
Table 5-6. Service Parameters
10PIN-key code
0 to 999911Capability to assign up to 10 PIN-key codes (for 10 different operators)
14Creep speed –10 to 101–5Defines how much output the power amplifier gives when you reach the first speed sensor.
–10 = low speed when reaching first speed sensor
10 = high speed when reaching first speed sensor
20Hour meter selection
21Battery size
1 to 5121 (A.) = key time
2 (b.) = activity time
3 (c.) = drive
4 (d.) = lift
5 (s.) = time to service
1 to 2018Battery size selection
25Service interval hours0 to 2000500Sets/resets service timer. C29 displays when time is up. To reset timer, access this parameter without changing the value.
39Access code
Parameter Description
Parameter 1
1 to 413Defines what access level service personnel have to parameters.
1 = key switch/operator parameters open, 2 = key switch/operator parameters closed, 3 = keypad/operator parameters open, 4 = keypad/operator parameters closed (when closed, Service Key is required to access truck parameters).
Parameter 4
Maximum speed value sent to the power amplifier while in Slow mode except during Turtle Torque (gives torque boost if high load is encountered).
Parameter 2
Top Speed - Reduces speed value sent from the ETAC to the power amplifier while in Fast mode (all throttle positions).
Parameter 3
Acceleration - Defines the truck’s acceleration characteristic when the truck starts from a stop. A high number gives maximum acceleration, a lower number gives less aggressive acceleration.
00700-CL340-05, Issued: 2 May
Auto-Plug Braking in Neutral - Defines the truck’s automatic plug-braking characteristic when throttle is reduced (including to neutral). A lower number gives less aggressive deceleration.
Parameter 5
Automatic Time Off Interval (touch pad only)The time until the truck is switched OFF (energy saving feature) when the truck is idle and the brake is applied. Time is counted from when the latest power output is requested. If truck has key switch option, the truck never powers OFF. Range is from 1 minute to 20 minutes (a setting of ‘0’ disables automatic time off).