6.16 Raw Water Pump with Connections 6.16.1 DANGER
WARNING
Raw water pump – Relief bore check Rotating and moving engine parts. Risk of crushing, danger of parts of the body being caught or pulled in! • Only run the engine at low power. Keep away from the engine's danger zone.
High level of engine noise when the engine is running. Risk of damage to hearing! • Wear ear protectors.
Raw water pump – Relief bore check 1. 2. 3.
TIM-ID: 0000015173 - 005
4.
Check relief bore for oil and coolant discharge. Stop engine (→ Page 86) and disable engine start. Clean the relief bore with a wire if it is dirty. • Permissible engine coolant discharge: up to 10 drops per hour; • Permissible oil discharge: up to 5 drops per hour. If discharge exceeds the specified limits, contact Service.
MS150068/01E 2014-01 | Task Description | 249