Working Range Limiter 1.4 Operating Working Range Limiter
1.4.4
Entering limiting values for maximum slewing angles This section presupposes that the values for the maximum slewing angles are unknown and therefore describes the input by starting the switching points. For this, the following prerequisites must be fulfilled:
à
Entering limiting values manually, p. 1 - 17, – manual entry is switched off; – slewing angle monitoring is switched off; Switching monitoring off, p. 1 - 20.
H H Displays in submenu Working
Range Limiter
à
If the monitoring is switched on, you cannot start any larger limiting value as the monitoring would switch off crane movement. If manual entry is switched on, you cannot adopt the values for the currently started switching point. You can cancel the following entry at any time by pressing the Exit submenu/ entry mode ( ) button once. The red bar under the selected entry goes out.
ö
Definition: A displayed 0° angle means that the superstructure is turned backwards (is therefore in the 0° to the rear working position. A complete rotation out of this working position is separated into two semicircles for the display: – angles in right semicircle are displayed positively (0° to +180,0°), – angles in left semicircle are displayed negatively (0° to –179,9°). In the Maximum/current slewing angle display (2), the middle value (surrounded in blue) displays the angle for the current position of the superstructure. The upper value (surrounded in red) displays the set value for slewing angle A. The lower value (surrounded in red) displays the set value for slewing angle B.
• To enter slewing angle A or B, press the button next to the Maximum slewing angle entry submenu symbol (1) once.
05.02.2001
The Maximum slewing angle entry submenu opens.
s Operating instructions Working Range Limiter
2 084 658 en
1 - 11