2 minute read

1.4.7 Switching monitoring on and off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

1.4.7 Switching monitoring on and off

Switching monitoring on After the ignition is switched on, all monitoring functions are switched on that were on before the ignition was switched off.

HAfter switching on the monitoring, all of the driving gears' speeds are limited to a maximum of 50 %. This is also valid for the driving gear where higher values are set in the submenu Driving gear speeds. Limits under 50 % continue to be active. A limit between 30 and 50 % is recommended for the slewing gear speed.

The monitoring is switched on with the buttons under symbols (4) to (7). When the monitoring is switched off, the background to the corresponding symbols is black.

• Press the button under the desired symbol once (e.g. under symbol (6) for monitoring the slewing angle). The background to the symbol is now yellow and the monitoring is switched on. Those limiting values are monitored that are entered in displays (1) to (3) (à Read entered limiting values, p. 1 - 8).

GDanger of accident due to erroneously set limit values! If, during starting operations or after entering new limit values, you switch on the monitoring, then make sure that the settings for the limit values are correct. Start up the limit value slowly and check whether the movement has been switched off at the right time. If necessary, enter new values with a larger safety distance.

s

The Working Range Limiter display presents the limiting values pictorially. As soon as a monitoring function is switched on, the Working

Range Limiter display shows: – a red circle for the working radius, – a sector of a circle for the permissible slewing angle (A – B), – points joined by lines for monitored objects (e.g. (1 – 3) or (4 – 6)), – a cross (7) for the current boom position.

There is no presentation for the total height.

HWhen the monitoring is switched on, it is impossible to drive behind a defined object.

Switching monitoring off After the ignition is switched on, all monitoring functions are switched off that were off before the ignition was switched off.

The monitoring is switched off with the buttons under symbols (4) to (7). When the monitoring is switched on, the background to the corresponding symbols is yellow. • Press the button under the desired symbol once (e.g. under symbol (6) for monitoring the slewing angle). The background to the symbol is now black and the monitoring is switched off. The optical presentation for this monitoring goes out on the Working Range Limiter display (e.g. the circle section for monitoring the slewing angle).

HDisplays (1) to (3) show the last entered limiting value, even when monitoring is switched off. The black symbol is always the standard for switching off.

This article is from: