3-8
Maintenance plan (overview)
):
):
):
Check the function of the following assemblies/components. Rectify if necessary: • Lights, signalling system, acoustic warning system 15 • Heating function 16
Functional check (
Check the refrigerant
● ●
● ●
●
Compressor oil 14 ●
●
Every 1000 s/h once a year ●
●
●
Every 1500 s/h
Replace dehumidifier and refrigerant 12
Check dehumidifier for corrosion, condensation and air bubbles
● ● ● ● ● ● ● ●
Every 500 s/h
Replace cab filter
Perform the following maintenance and inspection work: • Function of air conditioning 11
Air conditioning (
Lubricate the following assemblies/components – see Maintenance label on page 3-4: • Stabilizer blade • Swivelling console • Boom • Stick • Attachments • Hydraulic quickhitch (option) • Powertilt • Grease strip on chassis – see Lubrication strip on page 3-46
Lubrication service (
Service 50 s/h ●
●
Every 250 s/h
Actuate Powertilt swivel device in final position for 1 minute13
Maintenance work (once a day) ●
● ● ● ● ● ● ● ●
●
●
● ●
●
●
●
●
●
●
●
workshop
Check Powertilt for axial play (must not be over 0.38 mm.)
Maintenance plan/service hours (s/h)
Customer
Check the Powertilt for damage
For service and maintenance work on the attachment, please refer to the operation and maintenance manual of the attachment manufacturer as well.
Work description
3.3
Maintenance Authorized
SHB 38Z3 en – Edition 2.2 * 38z3s311.fm