Toyota Forklift 7SLL12.5 7SLL16 7SLL20 7SLL13.5S 7SLL12.5F 7SLL16F 7SLL20F Service Manual SN 985777

Page 109

Electrical systems – 5000 Parameters Order number 249896-040

Date 2007-05-11

Valid from serial number 985777-

T-code 789, 790, 791, 817, 818

11.5.6 Summary of driver parameters NOTE! Before changing any parameters, ensure you have read and understood the procedures for viewing and setting parameters in sections “11.5.2 Viewing parameters -CAN key not connected” on page 38 and “11.5.6 Summary of driver parameters” on page 41

See also section “11.4.4 Speed limitation” on page 34 for information regarding the maximum speeds of the truck.

Parameter

Table 14: Summary of driver parameters

02

Name

Unit

Min. Max. Step Std. Note

Maximum speed, high range

%

10

100

5

100 S 10:

100:

S= maximum speed 03

Maximum acceleration

%

10

100

5

80 A 10:

100:

A= maximum acceleration 04

Neutral braking effect

%

5

100

5

70 F 5:

100:

F= neutral brake force 06

Maximum speed -low range

%

10

100

5

100 S 10:

100:

S= maximum speed 07

Maximum speed- “Turtle”

%

10

100

5

60 S 10:

100:

S= maximum speed

© TIEE SARL