THE MAIN CHANGES
Introduction of Rotary Pump:
•The earlier form of in-line pump used to generate 600 bar of injection pressure which was not sufficient enough to inject the fuel in enhance rate of atomization
•With the introduction of rotary fuel injection pump the pump pressure is increased upto 800 bar resulting into optimum atomization of fuel with enhanced pressure along with constant rate of fuel delivery 118