Operation – Emergency procedures

6.7

Emergency procedures

6.7.1

Disconnecting the battery In event of emergency, e.g. in case of a cable fire, disconnect the battery from the vehicle network. 1. Flip open the cap. ð The pole clamp comes off the minus pole. 2. Remove the pole clamp from the battery and place it aside. B-834-0339

Fig. 80

6.7.2

Deactivating the reversing protection The reversing protection protects the operator from being crushed between the machine and an obstacle during reverse travel. If reversing protection is activated, the machine brakes to a standstill. The travel lever is disengaged by the reversing protection, the machine cannot be moved forward or backward.