Checks prior to start up – Daily maintenance

5.3.3 Checkingthehydraulicoillevel

NOTICE!

Components may get damaged!

–Check the hydraulic oil level at room temperature (approx. 20 °C (68 °F)).

–If, during the daily inspection of the oil level the hydraulic oil level is found to have dropped, check all lines, hoses and components for leaks.

–Use only oil of the permitted specification ÄChapter 8.2.4.1 ‘Hydraulic oil’ on page 107.

Protective equipment: n Working clothes n Safety shoes n Protective gloves

1. Check the oil level in the inspection glass.

Normal level approx. 1/2 height of inspection glass

Minimum level approx. 1/3 height of inspection glass

2. Unscrew the covering plate to refill.

3. Clean the area around the filling port.

Checks prior to start up – Daily maintenance

4. Unscrew the cap and fill in oil through a funnel with screen filter.

5. Retighten the cap and covering plate. HV 32