Proportional MV TC short circuit to +12 V, output Main clutch proportional valve K+ (MV main clutch short circuit to +12 V)
MV forwards direction TC circuit open, output
MV forwards direction TC short circuit to ground/earth, output
MV forwards direction TC short circuit to +12 V, output
MV reverse direction TC circuit open, output
MV reverse direction TC short circuit to ground/earth, output
MV reverse direction TC short circuit to +12 V, output
MV MVKL TC circuit open, output
MV MVKL TC short circuit to ground/earth, output
MV MVKL TC short circuit to +12 V, output
Alarm light display TC circuit open, output
Alarm light display TC short circuit to ground/earth, output
Alarm light display TC short circuit to +12 V, output
Tractor config. TC possible error
Clutch pedal E2P TC possible error
Main clutch pressure TC possible error
0x94
0x79
0x80
0x95
0x82
0x83
0x96
0x27
0x28
0x29
0x15
0x16
0x17
0x99
0x70
0x11
Proportional valve main clutch LU (MV main clutch not connected)
53
21/12/2004, 10.48
Invalid EEPROM data (main clutch contact pressure) (main clutch contact pressure incorrect)
Invalid calibration data (EEprom) clutch pedal sensor system (forward) (clutch pedal calibration values incorrect)
EEPROM end of line data invalid (vehicle configuration) (tractor configuration incorrect)
Warning lamp K+(oil pressure / main clutch overspeeding) (alarm LED short circuit to +12 V)
Warning lamp KM (oil pressure / main clutch overspeeding) (alarm LED short circuit to ground/earth)
Warning lamp LU (oil pressure / main clutch overspeeding) (alarm LED not connected)
MVKL valve K+ (MV MVKL short circuit to +12 V)
MVKL valve KM (MV MVKL short circuit to ground/earth)
MVKL valve LU (MV MVKL not connected)
Directional valve reverse K+ (MV reverse direction of travel short circuit to +12 V)
Directional valve reverse KM (MV reverse direction of travel short ciruit to ground/earth)
Directional valve reverse LU (MV reverse direction of travel not connected)
Directional valve forward K+ (MV forwards direction of travel short circuit to +12 V)
Directional valve forward KM (MV forwards direction of travel short circuit to ground/earth)
Directional valve forward LU (MV forwards direction of travel not connected)
Proportional valve main clutch KM (MV main clutch short circuit to ground/earth)
Proportional MV TC circuit open, output
Proportional MV TC short circuit to ground/earth, output
0x77
Holding valve 2 K+ (holding MV2 short circuit to +12 V)
Description
0x76
Holding MV 2 TC short circuit to +12 V, output
0x32
C O D E Displayed on Infocenter ZF Message
CHAPTER 3 Use