1 minute read

Heating system

CHAPTER 3 Use

IMPORTANT: do not continue to operate the controls when the implement cylinder has reached the end of its stroke in order to avoid prolonged operation of the pressure relief valve. This could cause the oil to overheat and cause damage to the hydraulic system and transmission.

Connection of an implement to the auxiliary hydraulic service couplers N.B. - the hydraulic couplers have 1/2” female fittings that allow connection under pressure of the male fitting on the implement hose. The couplers are also designed to disconnect automatically if accidentally jerked.

IMPORTANT: check that connection hoses are of sufficient length to allow unimpeded manoeuvring of the tractor and implement.

Before to disconnect the hoses, put in NEUTRAL the involved control units. To disconnect the hoses, push the hose into the coupler while pushing the ring on the coupler forward towards the tractor, then quickly pull back on the hose to release it from the coupler.

Clean the rubber covers carefully and insert them in the couplers.

IMPORTANT: the hydraulic service couplers are equipped with a tray to collect any oil spilt when hydraulically connecting an external implement. If this oil is to be re-utilised, it must first be properly filtered.

1 2 3 4

82

Sezione 3.pmd 82 7181-361

G=1/2"

7181-362

21/12/2004, 10.50

This article is from: