12.2. General errors

Problem

Automatic mode cannot be called up. An acoustic signal sounds and the message “PTO shaft switched on!” appears.

Floor conveyor not running. Set floor conveyor speed is equal to zero. • Increase the set floor conveyor speed. The return line has excessive back-pressure. • Check the tractor hydraulics (filter blocked). • Connect a return line (larger hose diameter) to the hydraulic connection “Pressure-free return” .

12.2 General errors

Cause, remedy

PTO shaft switched on • Disengage the PTO shaft The conditions for automatic mode are not fulfilled. • Comply with the conditions – see Notes concerning automatic operation, page 75.

Following the policy of CLAAS KGaA mbH of continuous product improvement to keep abreast of technical development, we reserve the right to make modifications which must not necessarily correspond to the text and illustrations contained in this operator's manual, and this without assuming the obligation to modify any machines previously delivered. Technical specifications, dimensions and weights are understood with the usual tolerances. Responsibility for errors and omissions not accepted. Reproduction or translation, in whole or part, only with written authorization by CLAAS KGaA mbH. All rights under the provision of the Copyright act are reserved. CLAAS KGaA mbH 33426 Harsewinkel Germany Our contribution to the environment: CLAAS have printed this manual on 100% chlorine free paper.