OPERATING INSTRUCTIONS RH 200 Inspection and servicing
Plan A - after every 250 OH (at 250, 750, 1250 ... OH)
Plan B - after every 500 OH (at 500, 1500, 2500 ... OH)
Plan C - after every 1000 OH (at 1000, 2000, 3000, 4000 ... OH)
Plan D - after every 5000 OH (at 5000, 15000, 25000 ... OH)
Plan E - after every 10000 OH (at 10000, 20000, 30000, ... OH) Page 6 von 8 Location
Servicing work
Menge / No.
Pump transfer gearbox - Breather filter
Carry out oil analysis
2
#
#
#
Change oil
13
#
#
#
#
2
#
#
#
#
#
#
#
#
2x1
#
#
#
Check for contamination and damage
2x1
#
#
#
Replace
2x1
#
#
#
#
Clean
2x1
Replace
2x1
- Pre-chamber
Change oil
2x5
- Breather filter
Clean
Oil filter
Slewing gearbox
Plan Plan Plan Plan Plan B A C D E
Carry out oil analysis
4 13
#
#
Change oil
4
- Breather filter
Replace
4x1
Travel gearbox
Carry out oil analysis
2
#
Check oil level
2
#
Change oil
2
13
- Magnetic rod
Clean
2x1
Pre-chambers
Check oil level
2x1
- Magnetic rod Brake chambers Breather filter
2x1
Clean
2x2
Clean
2x3
Replace
2x3
Gearing / pinion
Check condition
Fastening screws (slewing ring, undercarriage and superstructure)
Check for tightness (cf. Technical Handbook)
1
# #
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
13
2x2
Check grease filling
13
2x2
Change oil
Slewing ring
#
# #
13
Change oil Check oil level
#
# #
#
#
#
#
#
#
#
#
#
cf. “Refilling quantities – Oil“ table
3-24