1 minute read
OPERATING INSTRUCTIONS RH 200
Inspection and servicing
AIR-INTAKE SYSTEM
Read and observe the "EngineSafety instructions" chapter.
Main filter elements
Insufficient air-intake performance, caused by acontaminated main filter element, is displayed on the BCS-screen (Fig. 3-36:).
Clean or renew main filter elements only if the BCS displays a warning on the screen (Fig. 3-36:) with the engines running at high speed.
Risk of injury caused by rotating or hot parts of the engine.
Shut off the engines before working on the airintake system.
Secure the machine as described in the "Securing the machine" section.
Do not start the engine when parts of the air-intake system have been detached.
Engine damage may occur if the engine is allowed to draw in unfiltered air.
Each engine is equipped with four dry-air filters (Fig. 3-35:) consisting of main and safety filter element.
Removal and installation
" Unscrew nut (1, Fig. 3-35:) and remove cover (2).
" Unscrew nut (4) and withdraw main filter element (5). Do not loose the washer under nut (4).
" Replace or clean main filter element
New or cleaned main filter elements should always be at hand to shorten excavator downtimes.
Operating Instructions Rh 200
Inspection and servicing
Before installing the filter element, clean contact faces at cover (2, Fig. 3-37:) and at filter housing.
" Put on cover (2) and tighten nut (1).
During the removal of the main filter element, the safety element (7, Fig. 3-38:) must remain in the filter housing.
Checking and cleaning the main filter element
Examine the filter paper of the element with a lamp which is introduced into the element (Fig. 3-39:). Any damage is then clearly visible.
Replace damaged or deformed elements immediately.
Check element seal. When the seal is damaged, the filter element must be replaced, too.
Cleaning with compressed air is suitable if the filter element is to be re-used immediately.
Blow filter element (Fig. 3-40:) clean with dry compressed air from the inside by moving the compressed-air gun up and down.
The pressure at the nozzle must not exceed 6 bars.
Cleaning is terminated when all visible dust has been blown out of the filter element.
Never clean filter element by beating against hard objects.
Replace the main filter element after 1000 operating hours or 3 cleaning cycles; and, after one year of operation at the latest.