OPERATING INSTRUCTIONS RH 40 E Inspection and servicing
Plan A - after every 250 OH (at 250, 750, 1250 ... OH)
Plan B - after every 500 OH (at 500, 1500, 2500 ... OH)
Plan C - after every 1000 OH (at 1000, 2000, 3000, 4000 ... OH)
Plan D - after every 5000 OH (at 5000, 15000, 25000 ... OH)
Plan E - after every 10000 OH (at 10000, 20000, 30000, ... OH) Page 3 von 4 Location
Servicing work
Menge / No.
Plan Plan Plan Plan Plan B A C D E
Check pressure (cf. Technical handbook)
#
#
#
- Fastening screw
Check for tightness
#
#
#
- Rubber bearing
Check condition
#
#
#
Return-flow filter
Replace
#
#
#
Hydraulic system Oil cooler - Bearing
High-pressure filter Magnetic rod
4
Check / clean
2
Replace
2
Check / clean
3
#
# #
#
#
#
#
#
#
#
#
#
Bypass valve (working circuit) Clean valve
2
#
Bypass valve (cooling circuit)
1
#
Check / clean filter sieve
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
Change valve
1
Check for contamination and damage
1
Replace
1
Check for contamination and damage
1
Replace
1
Breather filter
Replace
1
Hydraulic oil reservoir
Carry out oil analysis
1
Change oil
8 9
#
1
#
Filter (pilot control circuit)
Filter (slewing mechanism pump feeding-circuit)
1
Pressure accumulator
Check pressure (cf. Technical handbook)
Cylinder (seals and guide rings)
Replace
Plan A - after every 250 OH (at 250, 750, 1250 ... OH)
8
#
#
#
#
Plan B - after every 500 OH (at 500, 1500, 2500 ... OH)
cf. “Refilling quantities – Oil“ table
9
Unless it is regulary analyzed, the hydraulic oil must be changed every 5000 OH or after 3 years at the latest
BA RH40E(3 664 930.00)-EN
3-23