OPERATING INSTRUCTIONS RH 40 E
Inspection and servicing
Water trap (option)
Water contained in the fuel is removed by the water trap (Fig. 3-39:).
Servicing
Draining off water
Carry out the following works in accordance with the servicing schedule and at regular intervals:
" Loosen venting plug (9, Fig. 3-40:) and leave drain valve (3) open until there is no more water in the diesel fuel flowing out of the valve.
Collect escaping liquid in a recipient suitable for diesel fuel and discard without polluting the environment.
The liquid flowing out of the valve flushes and cleans the filter element(6) von from top to bottom.