
1 minute read
OPERATING INSTRUCTIONS RH 40 E
Inspection and servicing
Depressurizing
" Park the excavator on a horizontal surface.
" Set the working equipment on the ground.
" Shut off the drive engine.
Sections 1 and 2: servo control and working hydraulics
- Shift both control levers repeatedly into all dIrections (Fig. 3-51:).
Topping up with hydraulic oil
" Remove cover (20, Fig. 3-53:) and retaining disk (23).
" One of the return-flow filters is now visible in the filter chamber.
Fig. 3-51:
Section 3: return-flow line
After shutting down the engine, the precharging pressure decreases rapidly through the precharging valve. No measures are required before opening the return-flow line.
Checking the hydraulic oil level
" Bring hydraulic oil to operating temperature (abt. 50 °C).
" Park the machine on a horizontal surface.
" Move all hydraulic cylinders to their central positions.
The oil level must lie between the ½ and ¾ marks of the inspection glass (1, Fig. 3-52:).
" Fill in hydraulic oil through this return-flow filter until the oil level lies between the ½ and ¾ marks of the inspection glass (oil grade cf. "Refilling quantities - Oil").
" Before fitting retaining disk (23) and cover (20), check sealing ring (26) and replace if damaged.
" Fit cover together with sealing ring.