BI015807
OPERATING INSTRUCTIONS RH 400 Operation EMERGENCY STOP pushbuttons The entire electrical system is switched off with the EMERGENCY STOP pushbuttons.
§
on the righthand side at the counterweight This latter one is operate with the rope (3, Fig. 2-21:)
In an emergency, press the EMERGENCY stop. The EMERGENCY STOP pushbuttons are located §
in the control column in the driver's cab (31, Fig. 2-19:)
Fig. 2-21:
The electrical system of the excavator can be switched on after the EMERGENCY SHUTOFF buttons are activated. Fig. 2-19:
§
in the control cabinet (2, Fig. 2-20:)
Ü Pull the button (31, Fig. 2-19:) out Ü Pull the button (2, Fig. 2-20:) out Ü Pull the locking (5, Fig. 2-21:) out
Fig. 2-20:
Fig. 2-22:
2-17
Update to version .01, see pages 3-25 and 3-93a
BA RH400(3 659 450.00)-EN