4 minute read

High beam lights indicator. 58 Information center display

TRAININGMANUAL

PROGRAMMINGTHEINFORMATIONCENTER

Display field numbers and description Field number Item StatusIndications possibles

100 Transmission ECM (EST 37) 62101 - 72101 - 82101 - 92101 Identification number

101 Transmission ECM (EST 37) 62101 - 72101 - 82101 - 92101 Identification number

102 Transmission ECM Identification Lock 000: Fields 100 and 101 are the same and are locked and Reprogram Set 001: Fields 100 and 101 are unlocked (may be changed) 010: Reprogram the transmission ECM 1xx: the 1ist1 shows that 100 and 101 are diffèrents

103 Transmission ECM Identification 0 - - = No data received from Transmission ECM Reprogramming result 1 - - = Data received from Transmission ECM 100 = TECM Identification Numbers are the same. 101 = TECM Identification Numbers are different 110 = TECM ID.N have been successfully reprogrammed. 111 111 = TECM ID.Nrs not present as received

104 to 113 Reserved for future machine information

114 Beginning numbers of Case Cluster Part Number 115 Remaining numbers of Case Cluster Part Number

116 Cluster production date code (yr ñ day) Example: 96 135

117 to 120 Reserved for future use

130 Tire Size Calibration for speedometer 131 to 139 Dedicated to tire calibration numbers

140 to 160 Reserved for future use

171 to 190 Resettable Fault Code #1 Through Fault Code #10172, 174, 176, 178, 180, 182, 184, 186, 188, 190Hour Code #1 Through Hour Code #10. Hour Codes Follow Resettable Fault Codes Respectively. 197 Input analogue data read by the microprocessor. Voltages read by the microprocessor will not exceed 5 volts When “13” is entered in this location, the analogue data inputs to the microprocessor will be displayed in location 000 to location 015. It is read as 0 = 0 volts and 1023 = 5 volts. When the Information Center is turned off, location 197 will reset back to 0 and normal gauge indications will be read in the display center in location 000 to location 015.

NOTE : In the fields 100 and 101 new codes ending per 02 may be shown. This is for future uses.

TRAININGMANUAL

PROGRAMMINGTHEINFORMATIONCENTER

Transmission Identification Numbers

Locations 100 and 101 will display the transmission electronic control module(ECM) identification numbers. These numbers should match the machine model that the transmission ECM is installed in. Both locations must have the same numbers in them for the machine to function properly.

It is possible that a service technician may have to set these identification numbers if a new ECM is installed on a machine. The actual storage of the codes is stored in positions 100 and 101, however, you must use positions 102 and 103 to make the changes kept in 100 and 101.

You must also have the park brake engaged to change the transmission identification numbers.

Up count Program

Down count Reset

The first step is to unlock positions 100 and 101 so that they can be changed. This is done in position 102.

1Press the Up/Down Count switch to the up position until 102 is shown in the display. NOTE: Locations 098 and 099 must be set to 21 before position 102 can be accessed. 2Press the Program/Reset switch back to the center position. 3Press the Up/Down Count switch to the up position until 001 is in the display.

The next step is to change the transmission ECM numbers

4Press the Program/Reset switch back to the program position. 5Press the Up/Down Count switch to the down position to display location 101. 6Press the Program/Reset switch back to the center position. 7Press the Up/Down Count switch to the up position until the appropriate code is in the display. Use the table on page 4.A.25.00 to select the correct code for the machine model number. 8Press the Program/Reset switch back to the program position 9Press the Up/Down Count switch to the down position to display location 100 10Press the Program/Reset switch back to the center position. 11Press the Up/Down Count switch to the up position until the appropriate code is in the display. Use the table on page 4.A.25.00 to select the correct code for the machine model number.

LThe next step in the process is to instruct the information center to reprogram the transmission controller.

12Press the Program/Reset switch back to the program position. 13Press the Up/Down Count switch to the up position until 102 is shown in the display. 14Press the Program/Reset switch back to the center position. 15Press the Up/Down Count switch to the up position until 010 is in the display. 16Press the Program/Reset switch back to the program position. 17Press the Up/Down Count switch to the up position until 103 is shown in the display. 18Press the Program/Reset switch back to the center position. If the transmission ECM was successfully programmed you should see a 110 in the display. If it was not successfully programmed refer to the table below for interpretation of the code that is displayed and go back and fix the problem

The next step in the process is to lock the program numbers so that they cannot be changed.

19 Press the Program/Reset switch back to the program position. 20Press the Up/Down Count switch to the down position until 102 is shown in the display. 21Press the Up/Down Count switch back to the program position. 22Press the Up/Down Count switch to the up position until 000 is in the display. This locks locations 100 and 101. 23Press the Program/Reset switch to the reset position and hold for 0.25 seconds. 24Turn the key switch to the off position and restart the machine within 10 seconds or the programming will not be saved in the memory of the information center.