5 minute read

Engine coolant gauge 52 Engine oil pressure gauge

TRAININGMANUAL

PROGRAMMINGTHEINFORMATIONCENTER

Requested Gear Check

This test is designed to test the FNR/Shifting lever to see that it is functioning normally. It tests to see that the information center is reading the same gear that the lever is requesting. 1 Turn the key switch to the on position, do not start the machine. 2 Advance to display field number 028 using the programming entry procedure listed previously. 3 Press the Program/Reset switch back to the center position. You should see the appropriate code in the table below for the requested gear. The display should also flash the appropriate direction selected and gear number in the transmission display window. 4 Cycle through all gears in all directions(FNR) using the shifter lever and make sure the appropriate code is shown on the display for each gear requested. The correct codes are listed in the table below Forward 1 - Code 101 Neutral 1 – Code 201 Reverse 1 – Code 301 Forward 2 - Code 102 Neutral 2 – Code 202 Reverse 2 – Code 302 Forward 3 - Code 103 Neutral 3 – Code 203 Reverse 3 – Code 303 Forward 4 - Code 104 Neutral 4 – Code 204 5 Press the Program/Reset switch to the Reset position to exit the monitoring mode. 6 Turn the key switch to the off position.

Actual Gear Status

This test will check to determine that the actual gear the transmission is in, is the same as the gear that the information center is reading. It does not test the readings that the information center is receiving from the

FNR/Shifter lever. To perform this test the operator must have the transmission in the manual mode and drive the machine while performing the test. 1 Start the machine. 2 Advance to display field number 030 using the programming entry procedure listed previously. 3 Press the Program/Reset switch back to the center position. You should see the appropriate code in the table below for the requested gear the transmission is in. The display should also flash the appropriate direction selected and gear number in the transmission display window. 4 Cycle through all gears in all directions(FNR) using the shifter lever while driving the machine and make sure the appropriate code is shown on the display for each gear requested. The correct codes are listed in the table below.

Forward 1 - Code 101 Neutral 1 – Code 200 Reverse 1 – Code 301

Forward 2 - Code 102 Neutral 2 – Code 200 Reverse 2 – Code 302

Forward 3 - Code 103 Neutral 3 – Code 200 Reverse 3 – Code 303

Forward 4 - Code 104 Neutral 4 – Code 200

Limp homemode – 115 Limp home mode - 315 5 Press the Program/Reset switch to the Reset position to exit the monitoring mode. 6 Stop the machine, place it in neutral and apply the park brake. 7 Turn the key switch to the off position.

Master Indicator Status

This test is used to check the master indicator lights in the instrument cluster to make sure that the are functioning properly. 1 Start the machine. 2 Advance to display field number 039 using the programming entry procedure listed previously. The red warning indicator light will begin to flash. 3 Press the Program/Reset switch back to the center position. If everything is functioning normally in the information center the display will show 00 and the warning indicator will flash. If there is an error the display will show 01. The indicator will still flash. 4 Advance to display field number 041 using the programming entry procedure listed previously. The yellow caution indicator light will begin to flash. 5 Press the Program/Reset switch back to the center position. If everything is functioning normally in the information center the display will show 00 and the caution indicator will flash. If there is an error the display will show 01. The indicator will still flash. 6 Turn the key switch to the off position. Up count Program Down count Reset

TRAININGMANUAL

PROGRAMMINGTHEINFORMATIONCENTER

Master Reset

This feature will reset the information center values back to the original factory settings for the following features:

Gauge Display

Information Center Lighting Work Lights Off

Information Center Lighting Work Lights On

Minimum Gear Selection

Maximum Gear Selection

To set the features back to their original settings: 1 Turn the key switch to the on position, do not start the machine. 2 Advance to display field number 042 using the programming entry procedure listed previously. 3 Press the Program/Reset switch back to the center position. 4 Press the Up/Down Count switch to the up position twice to change the reading from 00 to 01. 5 Press and hold the Program/Reset switch to the momentary position for 0.25 seconds. 6 Turn the key switch to the off position.

Park Brake Switch Check

This will check operation of the park brake switch to make sure that it is functioning properly. This same check will also show if t the park brake indicator light is functioning. This check does not check the wiring from the information center to the park brake pressure switch.

1 Turn the key switch to the on position, do not start the machine. 2 Advance to display field number 043 using the programming entry procedure listed previously. The park brake light will flash intermittently. 3 Press the Program/Reset switch back to the center position. You should see a 00 in the display if the park brake switch is in the on position. 4 Toggle the park brake switch to the off position. You should see a 01 in the display when the switch is activated. 5 Press the Program/Reset switch to the Reset position to exit the monitoring mode. 6 Turn the key switch to the off position.

Redundant Brake Pressure Switch Check

This check will check operation of the redundant brake pressure switch and the wiring from the switch to information center to make sure that it is functioning properly. This same check will also check to see that the park brake indicator light is functioning. This check does not check the wiring from the information center to the park brake switch located in the cab.

1 Start the machine. 2 Advance to display field number 044 using the programming entry procedure listed previously. The park brake light will flash intermittently. 3 Press the Program/Reset switch back to the center position. You should see a 00 in the display if the brake pressure is in the normal operating range. The display will show 01 if the brake pressure is out of the normal operating range. 4 Press the Program/Reset switch to the Reset position to exit the monitoring mode. 5 Turn the key switch to the off position. Up count Program

Down count Reset