INSTRUMENTS/CONTROLS

4. TOGGLE SWITCH PANEL

1

2

8

15

16

3

4

7

5

6

9 10 11

17 18

1. SADDLE LOCK PIN SWITCH

20

12 13 14

19

4. MOLDBOARD FLOAT SWITCH - RIGHT SIDE

The saddle lock pin switch activates a solenoid valve which sends hydraulic fluid for cylinder rod movements to release and engage the saddle pins.

This switch activates or deactivates the moldboard float function for the Right side of the blade. To activate the float function, push the toggle switch away from the operator’s seat. To deactivate the float function, push the toggle switch towards the operator’s seat.

With the toggle switch pushed away from the operator’s seat, the pins remain retracted from the saddle and with the toggle switch pushed towards the operator’s seat, the pins will extend and engage the locator hole in the saddle.

5. FRONT BLADE FLOAT SWITCH This switch activates or deactivates the front blade float function. To activate the float function, push the toggle switch away from the operator’s seat. To deactivate the float function, push the toggle switch towards the operator’s seat.

Use the blade lift cylinders to assist movement of the saddle lock pins. 2. RIPPER / SCARIFIER SWITCH The ripper / scarifier switch activates a solenoid valve which sends hydraulic fluid to the rear ripper or the front scarifier cylinders.

6. MOLDBOARD ANTISHOCK FUNCTION SWITCH This switch activates and deactivates the moldboard cylinders antishock function. To activate the antishock function, push the toggle switch away from the operator’s seat. To deactivate the antishock function, push the toggle switch towards the operator’s seat.

To move the rear ripper, push the toggle switch away from the operator’s seat. To move the front scarifier, push the toggle switch towards the operator’s seat. 3. MOLDBOARD FLOAT SWITCH - LEFT SIDE This switch activates or deactivates the moldboard float function for the left side of the blade. To activate the float function, push the toggle switch away from the operator’s seat. To deactivate the float function, push the toggle switch towards the operator’s seat.

7. ENGINE LOGIC SWITCHES These switches are used to make the engine troubleshooting.