Calibrating the scale Calibrating the pallet truck scale T-code 805, 813, 830
Valid from serial number 3 300 000-
Date 2006-06-19
Order number 232020-040
10.1.2 Single-point calibration Deleting (resetting) previous calibrations • Press and hold the “PT” button for around 18 seconds - The display remains empty until calibration mode is accessed . - The indicator shows the value of the first calibration point, and the lowest indication bar (left side of the display) flashes. • The three previous programmed values can be checked on the screen by moving the indication bar up or down using the up and down button. - When the lowest indication bar lights up, the first (lowest) value is displayed, and above this bar are the second and third bars showing the highest value. - When calibrating just one point, the values for the next and the highest value should be zero. • Press and hold the “up” or “down” button until the middle calibration value is shown. - The middle indication bar flashes. • Press the “0/T” button. - The first segment flashes. • Use the “up” and “down” buttons to reset the flashing segment to zero. • Move to the next segment using the “0/T” button. • Reset all segments until the indication bar starts flashing. • Press and hold the “up” or “down” button until the highest calibration value is shown. - The highest indication bar flashes. • Repeat this process until all segments have been reset.
64
Service Manual
LHM200SC, LHM200SCQ, LHM200SCO
© BT Europe AB